This list of .msc files will help you run admin tools from the command line.
Most admin tools in Windows Server 2003 are MMC consoles you can access from the Start menu. But you can also open these console from the command line if you know their .msc filenames. This can be especially useful if you log on to your admin workstation using a limited privilege account and use Runas to perform admin tasks. For reference, here's a list of admin tools with their associated .msc files. You can print this out and tape it on the wall beside your workstation until you memorize the ones you use most commonly.
http://www.windowsnetworking.com/kbase/windowstips/windows2003/admintips/admin/launchadmintoolsfromthecommandline.html
AD Domains and Trusts
domain.msc
Active Directory Management
admgmt.msc
AD Sites and Serrvices
dssite.msc
AD Users and COmputers
dsa.msc
ADSI Edit
adsiedit.msc
Authorization manager
azman.msc
Certification Authority Management
certsrv.msc
Certificate Templates
certtmpl.msc
Cluster Administrator
cluadmin.exe
Computer Management
compmgmt.msc
Component Services
comexp.msc
Configure Your Server
cys.exe
Device Manager
devmgmt.msc
DHCP Managment
dhcpmgmt.msc
Disk Defragmenter
dfrg.msc
Disk Manager
diskmgmt.msc
Distributed File System
dfsgui.msc
DNS Managment
dnsmgmt.msc
Event Viewer
eventvwr.msc
Indexing Service Management
ciadv.msc
IP Address Manage
ipaddrmgmt.msc
Licensing Manager
llsmgr.exe
Local Certificates Management
certmgr.msc
Local Group Policy Editor
gpedit.msc
Local Security Settings Manager
secpol.msc
Local Users and Groups Manager
lusrmgr.msc
Network Load balancing
nlbmgr.exe
Performance Montior
perfmon.msc
PKI Viewer
pkiview.msc
Public Key Managment
pkmgmt.msc
QoS Control Management
acssnap.msc
Remote Desktops
tsmmc.msc
Remote Storage Administration
rsadmin.msc
Removable Storage
ntmsmgr.msc
Removalbe Storage Operator Requests
ntmsoprq.msc
Routing and Remote Access Manager
rrasmgmt.msc
Resultant Set of Policy
rsop.msc
Schema management
schmmgmt.msc
Services Management
services.msc
Shared Folders
fsmgmt.msc
SID Security Migration
sidwalk.msc
Telephony Management
tapimgmt.msc
Terminal Server Configuration
tscc.msc
Terminal Server Licensing
licmgr.exe
Terminal Server Manager
tsadmin.exe
UDDI Services Managment
uddi.msc
Windows Mangement Instumentation
wmimgmt.msc
WINS Server manager
winsmgmt.msc
onsdag 21. september 2011
fredag 29. juli 2011
Find the Service tag or Serial number of VMware ESX host
There might be a few reasons that you would need to do this. But if you need to locate the Serial Number of server or Service Tag of your Dell server you can do this from the service console command line. In the past I have needed this to schedule service and also to confirm the identity of a server for the Vendor that was on site. In case you do not have a database to reference or maybe someone mistyped the digits you can always fall back to this method.
Type the following command from the command line on the service console and you will get some Vendor details and serial number information.
[root@host name]# /usr/sbin/dmidecode |grep -A4 “System Information”
Type the following command from the command line on the service console and you will get some Vendor details and serial number information.
[root@host name]# /usr/sbin/dmidecode |grep -A4 “System Information”
onsdag 12. januar 2011
inetpub\logs\logfiles\w3svc1 getting very large
http://social.technet.microsoft.com/Forums/en/configmgrgeneral/thread/d989b249-0159-41fc-b78c-1f1d91ce8bb3
Logfiles can be deleted / trimmed with the following command which creates a scheduled task to do it :-
at 12:00 /EVERY:Su Forfiles.exe -p C:\WINDOWS\system32\LogFiles\W3SVC1 -m *.log -d -30 -c \"Cmd.exe /C del @path\"
------------------------------------------------------
IIS logging is is enabled by default in IIs& ad IIS7.5 so I assume that you mean one of those: http://technet.microsoft.com/en-us/library/cc754631(WS.10).aspx.
Here we can disable the IIS log files
Go To IIS console -> and Right click WebSite Property and click web site TAB find the Enable logging Next Step ->Uncheck the Enable Logging and restart the IISADMIN services after restart the service IIS log files are disbled
--------------------------------------------------------------------------------
Logfiles can be deleted / trimmed with the following command which creates a scheduled task to do it :-
at 12:00 /EVERY:Su Forfiles.exe -p C:\WINDOWS\system32\LogFiles\W3SVC1 -m *.log -d -30 -c \"Cmd.exe /C del @path\"
------------------------------------------------------
IIS logging is is enabled by default in IIs& ad IIS7.5 so I assume that you mean one of those: http://technet.microsoft.com/en-us/library/cc754631(WS.10).aspx.
Here we can disable the IIS log files
Go To IIS console -> and Right click WebSite Property and click web site TAB find the Enable logging Next Step ->Uncheck the Enable Logging and restart the IISADMIN services after restart the service IIS log files are disbled
--------------------------------------------------------------------------------
fredag 7. januar 2011
How to check Oracle version / hvordan sjekke Oracle versjon?
SQL> connect system/manager@ as sysdba;
SQL> select * from v$version;
BANNER
----------------------------------------------------------------
Oracle9i Release 9.2.0.1.0 - Production
PL/SQL Release 9.2.0.1.0 - Production
CORE 9.2.0.1.0 Production
TNS for 32-bit Windows: Version 9.2.0.1.0 - Production
NLSRTL Version 9.2.0.1.0 - Production
SQL>
SQL> select * from v$version;
BANNER
----------------------------------------------------------------
Oracle9i Release 9.2.0.1.0 - Production
PL/SQL Release 9.2.0.1.0 - Production
CORE 9.2.0.1.0 Production
TNS for 32-bit Windows: Version 9.2.0.1.0 - Production
NLSRTL Version 9.2.0.1.0 - Production
SQL>
tirsdag 7. desember 2010
Fix på problem med ESX-host som har "disconnect" status i VirtualCenter
[root@tro-bl-esx02 root]# service mgmt-vmware restart
Stopping VMware ESX Server Management services:
VMware ESX Server Host Agent Watchdog [ OK ]
VMware ESX Server Host Agent [ OK ]
Starting VMware ESX Server Management services:
VMware ESX Server Host Agent (background) [ OK ]
Availability report startup (background) [ OK ]
[root@tro-bl-esx02 root]# service vmware-vpxa restart
Stopping vmware-vpxa: [ OK ]
Starting vmware-vpxa: [ OK ]
[root@tro-bl-esx02 root]#
Stopping VMware ESX Server Management services:
VMware ESX Server Host Agent Watchdog [ OK ]
VMware ESX Server Host Agent [ OK ]
Starting VMware ESX Server Management services:
VMware ESX Server Host Agent (background) [ OK ]
Availability report startup (background) [ OK ]
[root@tro-bl-esx02 root]# service vmware-vpxa restart
Stopping vmware-vpxa: [ OK ]
Starting vmware-vpxa: [ OK ]
[root@tro-bl-esx02 root]#
torsdag 2. desember 2010
How to upgrade iLO Firmware on c7000 blades
1. Last ned fila CP013601.scexe fra HP >> CP013601.scexe
2. Logg inn som root på ESX-server
3.Gi rettigheter til å kjøre fila >> chmod +x CP013601scexe
4. Bekreft oppgradering av firmware.
5. iLO firmware er oppgraert :-)
-----------------------------
[root@tro-bl-esx01 tmp]# chmod +x CP013601.scexe
[root@tro-bl-esx01 tmp]# ./CP013601.scexe
FLASH_iLO2 v1.12 for Linux (Aug 31 2009)
Copyright 2009 Hewlett-Packard Development Company, L.P.
Firmware image: ilo2_201.bin
Current iLO 2 firmware version 1.70; Serial number ILOCZJ80504HC
Component XML file: CP013601.xml
CP013601.xml reports firmware version 2.01
This operation will update the firmware on the
iLO 2 in this server with version 2.01.
Continue (y/N)?y
Current firmware is 1.70 (Dec 02 2008 17:50:39)
Firmware image is 0x300000 bytes
Committing to flash part...
******** DO NOT INTERRUPT! ********
Flashing completed!
Attempting to reset device.
Succeeded.
Waiting for iLO 2 to reboot...
iLO 2 reboot completed.
[root@tro-bl-esx01 tmp]#
2. Logg inn som root på ESX-server
3.Gi rettigheter til å kjøre fila >> chmod +x CP013601scexe
4. Bekreft oppgradering av firmware.
5. iLO firmware er oppgraert :-)
-----------------------------
[root@tro-bl-esx01 tmp]# chmod +x CP013601.scexe
[root@tro-bl-esx01 tmp]# ./CP013601.scexe
FLASH_iLO2 v1.12 for Linux (Aug 31 2009)
Copyright 2009 Hewlett-Packard Development Company, L.P.
Firmware image: ilo2_201.bin
Current iLO 2 firmware version 1.70; Serial number ILOCZJ80504HC
Component XML file: CP013601.xml
CP013601.xml reports firmware version 2.01
This operation will update the firmware on the
iLO 2 in this server with version 2.01.
Continue (y/N)?y
Current firmware is 1.70 (Dec 02 2008 17:50:39)
Firmware image is 0x300000 bytes
Committing to flash part...
******** DO NOT INTERRUPT! ********
Flashing completed!
Attempting to reset device.
Succeeded.
Waiting for iLO 2 to reboot...
iLO 2 reboot completed.
[root@tro-bl-esx01 tmp]#
fredag 19. november 2010
HP SIM Agent Configure on ESXi 4.1
http://communities.vmware.com/message/1590665
There is no HP Agent for ESXi. What you probably installed (at least I hope...) is the CIM offline bundle for HP.
Once you have those installed, you have to configure HP SIM to use WBEM (NOT SNMP) to communicate with the ESXi server. I actually had to do this very recently and documented it. See below:
1) Make sure the HP CIM bundle is installled. To do this, either install ESXi with the HP version of ESXi, or install the offline bundle downloaded from HPs site. To install the offline bundle:
1) Log onto VMWare VC Server
2) Go to Start Menu and Launch the VMWare CLI
3) Cd to the bin directory: c:\program files (x86)\Vmware\VmWAre vSphere CLI\bin
To Verify what patches in the bundle apply to your host:
Vihostupdate.pl --server servername --scan --bundle path to zip bundle
Vihostupdate.pl --server ah-esxi-exch --scan --bundle "C:\ESXi HP\hp-esxi4.1uX-bundle-1.0.zip"
Make
To install:
Vihostupdate.pl --server servername --install --bundle path to zip bundle
Vihostupdate.pl --server ah-esxi-exch --install --bundle "C:\ESXi HP\hp-esxi4.1uX-bundle-1.0.zip"
2) Go to HP SIM, and go to Options -> Discovery.
3) On the discovery screen, create a new discovery task. Add your ESXi hosts to the "Ping inclusion ranges/host names" text box.
4) CLick the blue Credentials button on the bottom (this is important).
5) CLick Show advanced protocol credentials.
6) Click the WBEM/WMI tab.
7) Enter in a valid username and password for your ESXi Host (I use root and the root password).
8) Click OK.
9) Now save the task by clicking Save.
10) Run the task by selecting it's radio button and clicking Run Now.
This should cause it to appear in HP SIM. Now, you need to setup WBEM indications (they replace SNMP traps).
To do this:
1) Log into Insight Manager on AH-Monitor1
2) Go to Options -> Events -> Subscribe to WBEM Events
3) Verify your server is in the Targets list (Click Add Target if necessary).
4) Click Next and finish the wizard to activate these events.
5) Reboot the ESXi Server to have this take effect.
There is no HP Agent for ESXi. What you probably installed (at least I hope...) is the CIM offline bundle for HP.
Once you have those installed, you have to configure HP SIM to use WBEM (NOT SNMP) to communicate with the ESXi server. I actually had to do this very recently and documented it. See below:
1) Make sure the HP CIM bundle is installled. To do this, either install ESXi with the HP version of ESXi, or install the offline bundle downloaded from HPs site. To install the offline bundle:
1) Log onto VMWare VC Server
2) Go to Start Menu and Launch the VMWare CLI
3) Cd to the bin directory: c:\program files (x86)\Vmware\VmWAre vSphere CLI\bin
To Verify what patches in the bundle apply to your host:
Vihostupdate.pl --server servername --scan --bundle path to zip bundle
Vihostupdate.pl --server ah-esxi-exch --scan --bundle "C:\ESXi HP\hp-esxi4.1uX-bundle-1.0.zip"
Make
To install:
Vihostupdate.pl --server servername --install --bundle path to zip bundle
Vihostupdate.pl --server ah-esxi-exch --install --bundle "C:\ESXi HP\hp-esxi4.1uX-bundle-1.0.zip"
2) Go to HP SIM, and go to Options -> Discovery.
3) On the discovery screen, create a new discovery task. Add your ESXi hosts to the "Ping inclusion ranges/host names" text box.
4) CLick the blue Credentials button on the bottom (this is important).
5) CLick Show advanced protocol credentials.
6) Click the WBEM/WMI tab.
7) Enter in a valid username and password for your ESXi Host (I use root and the root password).
8) Click OK.
9) Now save the task by clicking Save.
10) Run the task by selecting it's radio button and clicking Run Now.
This should cause it to appear in HP SIM. Now, you need to setup WBEM indications (they replace SNMP traps).
To do this:
1) Log into Insight Manager on AH-Monitor1
2) Go to Options -> Events -> Subscribe to WBEM Events
3) Verify your server is in the Targets list (Click Add Target if necessary).
4) Click Next and finish the wizard to activate these events.
5) Reboot the ESXi Server to have this take effect.
Abonner på: